    Brand Name : Iflow
    Model Number : YF-E100-5
    Certification : ISO9001, CE
    Price : negotiable
    Payment Terms : T/T, L/C
    Supply Ability : 2200000 units per year
    Delivery Time : 4-6 weeks
    • Product Details
    • Company Profile

    Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter

    sewage flow meter payable by electromagnetic flow meter DN100, PN16


    Description

    The electromagnetic flow meters are designed for measurement of conductive liquids. The magmeters have no moving parts and a PTFE lining, they can handle applications involving wastewater, pulp, food, and slurries. Standard outputs include analog, frequency, and RS485 communications. Optional sanitary tri-clamp mounting allows use of our flow meters in applications not previously open to magmeters. Local- and remote-display models are available.


    Advantages

    The magnetic flowmeter does not obstruct flow, so it can be applied to clean, sanitary, dirty, corrosive and abrasive liquids. Magnetic flowmeters can be applied to the flow of liquids that are conductive, so hydrocarbons and gases cannot be measured with this technology due to their non-conductive nature and gaseous state, respectively.

    Electromagnetic flowmeters do not require much upstream and downstream straight run so they can be installed in relatively short meter runs. Magnetic flowmeters typically require 3-5 diameters of upstream straight run and 0-3 diameters of downstream straight run measured from the plane of the magnetic flowmeter electrodes.


    Accuracy

    Pipe Dia (mm)Velocity (m/s)Accuracy
    3-20<0.3+ 0.25% FS
    0.3-1+ 1.0% Readout
    1-15+ 0.25% Readout
    25-6000.1-0.3+ 0.25% FS
    0.3-1+ 0.5% Readout
    1-15+ 0.3% Readout
    700-3000<0.3+ 0.25% FS
    0.3-1+ 1.0% Readout
    1-15+ 0.25% Readout

    Grounding

    From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.


    Technical data

    Product nameElectromagnetic flowmeter
    Product typeLocal|compact displayRemote displaySignal converter
    ModelIYF-EIYF-FIRT
    Pipe Diameter (mm)DN10-DN2000
    Power supply100-240 VAC / 18-36 VDC
    Accuracy+ 0.5%+ 0.5%+ 0.5%
    Power consumption<6w<6w<6w
    Enclosure ratingIP65IP68IP65
    Liquid temperature-25-120℃-25-120℃-25-120℃
    Ambient temperature-25-50℃-25-50℃-25-50℃
    Relative humidity10-90%10-90%10-90%
    Meter ratio1:1001:1001:100
    Flow directionBi-direction flowBi-direction flowBi-direction flow
    CommunicationRS485 / BacnetRS485 / BacnetRS485 / Bacnet
    Signal Output4-20mA/Pulse/Frequency4-20mA/Pulse/Frequency4-20mA/Pulse/Frequency

    Features

    • Virtually no pressure loss
    • Suitable to meter for wide range of conductive liquid media
    • No Moving Parts
    • Flanges port connection
    • RS485 Standard
    • Suitable for Pipes diameter p to 2000 mm
    • Large meter ratio
    • High Accuracy
    • 4 to 20 mA / Frequency / Pulse output

    Model selection

    Applicable metering liquid:

    • Conductive liquid media, conductivity > 5 µS/ cm
    • Various Conductive aqueous solutions, water solutions, acid & caustics
    • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
      water, effluent, fibrous, viscous, paper mill, food & beverage

    Non-applicable metering medial

    • Industrial gas, compressed air, steam, or liquid with large content of gas
    • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
      water, clean gas, etc.

    Notice on the selection of local type and remote type:

    Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
    remote type in the following conditions:

    • Ambient temperature or converter display sunshine temperature is over 60 ℃
    • High humidity or corrosive air existed
    • Serious pipe vibration
    • Magnetic meter need be suspended or submersible, uneasily read out
    • Other abrasive condition
    IModel
    YFElectromagnetic flowmeter
    TFTurbine
    VFVotex
    LXVane wheel
    TUltrasonic
    E/F display modeE: compact/local display, F: remote display
    Pipe DiaType (mm)
    xxxx

    15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

    500, 600, 800, 1000

    CodeAccuracy
    1+ 0.5% FS
    2+ 1.0% FS
    3+ 0.2% FS
    CodeType
    NConverter: 12 / 24 VDC, pulse output
    ATransmitter: 24VDC, 4-20mA outpt
    BIntelligent, Lion battery, no local display
    GSmart, local display, 4-20mA output
    C1Smart, local display, RS485
    C2Smart, local display, HART
    CodeType
    SCarbon steel housing
    LStainless steel housing
    GHigh pressure housing
    HL316L electrode
    HTiTitanium electrode
    HTaTantlum electrode
    HCHastelloy-C electrode
    L1Liquid media
    L2Gas media
    PPressure compensation
    TTemperature compensation
    PTPressure&Temp. Compensation
    FPTFE liner
    XRubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

    smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner


    Pipe Diameter, flow volume and product dimension

    DiaFlow volume (m3/h)Product dimension (mm)
    (mm)NormalMinMaxLDHH1
    151.50.069.515095272254
    202.50.1116.9105277254
    253.50.1826.5115283254
    3260.2943.6140297270
    40100.4567.8150307280
    50150.71106.0200165318294
    65251.19179.1185337313
    80401.81271.4200352326
    100602.83424.1250220371344
    1251004.42665250401372
    1501356.36954300285431403
    20025011.31696350340486460
    25037517.662650400395547511
    30054025.433817450445597565
    35073534.625195505657620
    40096045.226785500565717675
    450120057.238588550615757727
    50015007010602600670817782
    600216010015268780917782
    70029501382078170089510271068
    800385018027100800101511371157

    Industrial applications

    ChemicalFood & beveragePaper mill
    MetallurgyEnvironment protectionHydraulic
    MiningStainlessPetroleum
    PharmacyAir conditionerEffluent treatment plant
    Seawater desalinationPharmacyWater treatment

    Competitive advantage

    • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Process control

    Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter

    Calibration equipment

    Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter

    Quality Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai I Fluid Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)