Sign In | Join Free | My himfr.com
Home > Open Channel Flow Meter >

Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement

    Buy cheap Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement from wholesalers
     
    Buy cheap Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement from wholesalers
    • Buy cheap Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement from wholesalers
    • Buy cheap Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement from wholesalers

    Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement

    Ask Lasest Price
    Brand Name : Iflow
    Model Number : WG2
    Certification : ISO9001, CE
    Price : negotiable
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 5000 pieces per month
    Delivery Time : 1-2 weeks
    • Product Details
    • Company Profile

    Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement

    Open channel flowmeter, ultrasonic flow meters for waste water flow measurement, remote converter


    Technical data:

    • Type : Ultrasonic Open Channel Flowmeter
    • Medium : Clarified Water
    • Pressure : Atmospheric
    • Temperature : 0 ~ 500 C
    • Humidity : 95%
    • Channel Depth : 1.1 meters
    • Suspended Solids : <65 milligrams / liter
    • Level Measurement Range : 4 meters
    • Resolution : 1mm
    • Measuring Error : ± 0.2%
    • Temperature Compensation : Built in
    • Type : 2 Wire Loop
    • Power Supply : 24 VDC
    • Output : 4 ~ 20 mA DC
    • Display : LCD
    • Flow Linearization : Required
    • Table Entry : Local Key Pad
    • Housing : Aluminum, Epoxy Coated
    • Ingress Protection : IP67
    • Sensor Material : PVDF
    • Process Connection : 1.5" NPT ANSI B 1.20.1 Threaded
    • Beam Angle : 120
    • Cable Entry : 0.5" NPT ANSI B1.20.1
    • Locking Nut : Required

    The main function characteristics:

    • With a fully independent intellectual property rights.
    • Has wide range of temperature compensation and original ERD interference intelligent identification system, measurement data stability, high precision.
    • Six groups flow condition all data sending 485 serial ports output, PC directly receive, decimal shows, the convenient user record and read archived.
    • Original "fluid flow correction system" that flow coefficient according to slot size and level to be automatic operation weir and timing compensation.
    • The blackout time time, the year/month/day/when/points/SEC, flow data, using the ferroelectric double backup storage 10 years off.
    • Original "measuring tank jam recognition alarm system" can detect liquid slag quality measurement slot throat and obstruction caused by measurement.
    • Precise date determined when the calendar clock Settings, display and cooperate with the memo and time axis to file information records.
    • Has 4~20 mA three wire system, RS485, switch quantity and so on many kinds of signal output function selection.
    • Using intelligent measuring high, digital calibration, the user installation calibration simple and quick.
    • The ultrasonic non-contact measurement with no moving parts, flow without components within, no block sensor fault hidden trouble.

    Technical parameters

    • Applicable weir: Right angled triangle weir:The size of the opening 500mm
    • Rectangular weir:The size of the opening 250mm,500mm,750mm,1000mm
    • Bashir slot: Larynx way width: 25mm,51mm,76mm,152mm,228mm
    • Flow range:according to weir/flume size
    • Function characteris tics: data storage 1 year, can be arbitrary time of the inquiry
    • Flow precision: 1~5% F·S
    • Level range:2m
    • Level precision:±0.25% F·S (at times, and the blind process ℃)
    • Probe blind area:≤300mm (at 25 ℃)
    • Output signal:4~20 mA +RS485
    • Showing the way:16 LCD display,
    • Among them:Four level height,Four transient flow,Eight of the accumulative total flow,16 the calendar clock (buttons when)
    • Working temperature:-10~60℃(default),can be customized of level: 0~80℃
    • Work power:AC220V/50Hz,or DC24V/300m
    • Outlet way: instrument standard plugs, Liquid level meter quick connect,Installation:instrument wall hung installation; Sensor gongs grain installation M68×2.0mm, or gongs circle clampon installation
    • Protection level: IP66
    • Operation environment: constant pressure, not anti-explosion, not anti-corrosion

    Data sheet


    ModelWH
    Applicable weirsRight triangle weir slot (Open size: 500mm)
    Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm)
    Rectangular weir (Opening size: 250mm, 500mm, 750mm )
    Flow rangedepending on weirs dimensions to be used, up to 335000 m3/hr
    Flow precision5% FS
    Level range1m
    Level precision0.5% FS
    Sensor blind area<300mm @ 25C
    Output4-20 mA, tri wires
    DisplayLCD display, include: four levels
    four transient flow
    Eight of the accumulative total flow
    16 calendar clock
    Work temperature50C , customized available
    Power supplyAC220V
    Outlet waySensor leads 20m, instrument standard plugs
    Installationinstrument wall mount, sensor grain installation M49x1.5, or clamp on
    ProtectionIP66 (sensor)


    Dimensions
    Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
    Features

    • Built-in variety of algorithms, suitable for a variety of standard weirs.
    • Stable sensors - Suitable for harsh industrial situations
    • Isolated 4~20mA current output. Optional spot bus interface.
    • The blind zone can be manually set, shielding the probe near the interference signal.
    • Calibrated at Factory. And if required we shall do calibration at site.

    Sensors
    Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement
    Ultrasonic sensor Static pressure sensor
    Applications
    Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.
    Flow Totalizer parameters
    Flow measuring range: Depends on the size of the flume.
    Maximum Count: 9999999999
    Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
    Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
    flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
    has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
    Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.

    Output
    Voltage output: DC 12V or 24V
    Signal output: RS485/RS232; 4~20mA; 2 channel relay

    Triangle weirs
    Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
    Installation sample
    Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement

    Advantage
    The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.

    Quality Ultrasonic Open Channel Flow meter Converter Remote For Wastewater Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai I Fluid Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)